Property Inspected: | Lot 99, 5 Treewood Circuit Heathwood QLD |
Client: | Jon Doe |
Inspection Date and Time: | Thursday 16 January 2020 01:00 PM |
ID: | I09999
|
This document is partly based on Standards Australia Ltd copyrighted material that is distributed by SAI Global Ltd on Standards Australia Ltd's behalf. It may be reproduced and modified in accordance with the terms of SAI Global Ltd's Licence 1110-c028 to Report Systems Australia ("the Licensee")
1. Summary
This Summary MUST be read in full in conjunction with the rest of the Report. If there is a discrepancy between the information provided in this Summary and the body of the Report, the information in the body of the Report shall take precedence. Please read the Terms and Conditions
1.1 Summary of Observations
Handover Status:-
The Handover stage has been substantially achieved. The defects detailed in the body of the report will need to be addressed by the builder prior to occupancy.
A list of defects for the builder to address is provided at the end of this report.
Key Findings:-
- Structural Damage - No evidence found
- Timber Pest Activity - No evidence found
- Conditions Conducive to Structural Damage - No evidence found
- Conditions Conducive to Timber Pest Activity - No evidence found
Susceptibility to Termites:-
In the Consultant's opinion, the building's susceptibility to timber pests at the time of inspection is Low.
NOTE: This is a rating of the "susceptibility" of the building to termites or the "termite pressure" on the building. It should be viewed as the priority an owner should give to installing and maintaining a termite management system rather than an indication of whether or not termites are present.
Next Timber Pest Inspection:-
Following this inspection, the next inspection to help detect timber pest activity is recommended in 12 Months.
NOTE: The higher the susceptibility, the greater the frequency of recommended timber pest inspections.
Defect Causes and Cost of Repair:-
New Construction Handover Report does not establish the causes of defects identified.
Actions To Be Taken:-
Any recommendations made in this Report should be actioned promptly.
1.2. Service Agreement Details
Agreement Number | I052875 |
Date of Service Agreement | 16/01/2020 |
As requested and agreed with the Client, the inspection carried out by a qualified Building Consultant and Timber Pest Detection Consultant ("The Consultant") is a New Construction Handover Report ("The Report").
The Consultant provides an objective opinion about the condition of the property at the time of inspection.
1.3. Client Details
Client Name | Jon Doe |
Client Address | 99 High Road, Durack, QLD, 4077 |
Client Email Address | email@email.com |
Client Telephone | (W) (M) 0499 999 999 (H) |
1.4 Special Conditions / Instructions
1.5 Consultant Details
Consultant Name | Fred Smith |
Company Licence # | 1099999 |
Company Name | Australian Building Inspection Services Pty. Ltd. |
Postal Address | 17 Riverside Terrace, WINDAROO, QLD, 4207 |
Company Email | mailto:info@abis.com.au |
Company Telephone | 07 3804 1000 |
|
Important Note
Often it is very difficult to fully explain situations, problems, access restrictions, building faults or their importance in a manner readily understandable by the reader. Should you have any difficulty in understanding anything contained within this Report, you should contact the ABIS on 07 3804 1000 to have the matter explained.
2. General Property Description
The records of the appropriate local authority should be checked to determine or confirm whether the ground on which the building rests has been filled, is liable to subside, is subject to landslip or tidal inundation, or if it is flood prone.
General Description of the PropertyBuilding Type & Approximate Age | The new property is a detached slab-on-ground house |
Number of Storeys | One |
Building Position on Site | Towards the front of a small block |
Site Gradient | Gently sloping |
Site Access | Easy pedestrian and vehicular access |
Prevailing Weather Conditions at the Time of Inspection | Wet |
Site Drainage | Appears adequately drained |
Orientation Statement | The Consultant may use compass points in the report to assist in locating defects with the property. It is not intended to be an accurate statement of the true orientation of the building.
The facade of the building faces south.
Note: The facade of the building contains the main entrance door. |
3. Safety Issues and Hazards
This Section documents evidence of any item or matter (within the Consultant's expertise) that may constitute a present or imminent serious safety hazard. This should not be viewed however, as an audit or exhaustive list of safety issues relating to the property.
Safey hazards are identified out of a duty of care to those who may use or work on the property. If any of the hazards reported in this section are also a building defect they will also be reported on in the body of the report.
3.1 Identified Hazards
No hazards were identified during the inspection. See Note |
Most dwellings contain safety critical elements eg: structural fastenings, suspended floors, balconies, decks, stairs and balustrades. As failure of a safety critical element may result in serious injury or death, it is strongly recommended that any safety critical elements in a dwelling be inspected annually.
This report is not an safety audit and the client is warned that hazards and risks to safety may be present now or in the future that are not covered by this report. For their own safety, and as a duty of care to others, all home builders and owners must ensure safety hazards on their properties are eliminated. To assist the home owner in identifying and removing safety hazards, the Consultant recommends the home owner has an annual safety inspection conducted.
4. Timber Pests
The term Timber Pests covers one or more of the following wood destroying agents which attack timber in service and affect its structural properties:
- Fungal Decay - the microbiological degradation of timber caused by soft rot fungi and decay fungi, but does not include mould, which is a type of fungus that does not structurally damage wood.
- Wood Borers - wood destroying insects belonging to the order "Coleoptera" which commonly attack seasoned timber.
- Termites - wood destroying insects belonging to the order "Isoptera" which commonly attack seasoned timber.
Other insect pests (cockroaches, ants, etc) and vermin (rodents, possums, snakes, etc.) are not timber pests and are not covered by this inspection and report.
4.1 The Property's Susceptibility to Termites
Location Zone | 2.00 Zone C Brisbane Perth |
Age of Suburb | 0.00 Less than 10 years |
Distance to Boundary | 0.50 2 to 8 metres |
Wood in Garden and/or Under the House | 0.50 Small amount in yard |
Timber in Ground Contact | 0.00 None - Highset no bridging |
Timber Type Used in Construction | 0.00 Non timber frame |
Timber Exposure | 0.00 Timber in high and dry locations with human activity |
TOTAL SCORE | 3.00 |
SUSCEPTIBILITY TO ATTACK | Low |
NEXT INSPECTION DUE | 12 Months |
This model is based on the paper: RISK MODEL FOR TERMITE ATTACK IN AUSTRALIA - R.H. Leicester, C-H. Wang & L. J. Cookson - CSIRO
The higher the TOTAL SCORE on the above table, the greater the level of termite protection required. As a guide, the following table indicates the highest acceptable TOTAL SCORE for each type of Termite Management system (Barrier). This only applies if timber pest inspections are undertaken yearly or more frequently and the maintenance of the barrier is undertaken in accordance with manufacturers' specifications.
Barrier | Maximum acceptable TOTAL SCORE |
---|
Graded crushed stone or glass | 9.5 |
Stainless steel mesh | 10 |
Non-repellent toxic chemical | No Limit |
Repellent chemical | 14 |
No Barrier | 5.5 |
4.2 Termite Management
Observation | - Durable notice in electrical meter box indicating the possible installation of a termite barrier
Note: All relevant documents pertaining to the installation of any termite barrier system should be obtained from the builder by the building owner and kept on file including, any service warranties and advice in regard to the building owner's obligation to maintain the system. However, subterranean termites can bridge or breach barrier systems and thorough regular inspections of the building are necessary. |
Photos | |
Termite Management Systems
A termite management system is a system designed to reduce the risk of termites damaging a structure.
Typically a system consists of one or more of the following:
-
a treated zone created by a termiticidal chemical applied to the soil under or around a building (e.g. Biflex, Premise, Termidor)
-
an inspection zone created by a chemical-physical barrier system (e.g. Kordon, Homeguard)
-
an inspection zone created by a physical barrier system (e.g. Granitgard, TermiMesh, Termiglass)
-
a termite monitoring and baiting system (e.g., Exterra, Nemesis, Sentricon)
These systems are usually installed by a builder as a componant of a termite management system (recommended for all homes by the Queensland State government). For the risk of termite damage to be minimised, the owner must also matain the integrity and effectiveness of the barrier or treated zone, conduct annual termite inspections and prevent conditions conducive to timber pest arising in and around the property.
4.3 Timber Pest Activity and Conditions Conducive to Timber Pest Activity
This Section covers any timber pest issues. Any evidence of timber pest activity including termites, borers and fungal decay observed by the in spector are detailed in this section. In addition any conditions that create an environments which are likely to lead to timber pest avtivity (Refered to a Conditions Conducive to Timber Pest Activity) is also detailed in this section.
Conditions conducive to timber pest activity should be removed and any timber pests detected should be treated by a timber pest specialist.
5. The Yard
The term Yard covers the area of the property outside and around the main dwelling and includes the property's fences, the drainage of the ground around the home and any structures built in the yard.
5.1 Yard Areas Not Inspected
This Section details any yard areas that couldn't be accessed and were not included in the inspection.
All the normally accessible areas permitted entry |
5.2 Yard Structures
This Section covers any structurs outside and around the main building.
Yard Structures Inspection Completed |
5.3 Yard Walls and Fences
Yard walls and fences are the boundary walls and fences and other walls and fences within the yard area.
Yard Walls and Fences Inspection Completed |
5.4 Grounds
This Section covers the
ground area outside and around the property
Inspection of trees on the property for disease, stability and soundness is not within the scope of this inspection.
Note: Roots of trees and shrubs
can negatively impact footings by removing moisture from clay soils immediately underneath
the building causing subsidence as the clay shrinks.
In its
search for water, a tree root system can spread a lateral distance equal to the
height of the tree. If in rows or grouped with other trees, the roots may spread
up to twice the height of the tree.
In addition, trees closer
than their mature height may be blown over and/or fall onto and damage
buildings.
Care should be taken when selecting
trees and, as a guide, the trees listed in the table below should not be planted within the
distance of their mature height from the building depending on whether they are to be planted in a line or in a
group.
For further information see: A Simple how to Guide to Preventing Structural Damage
5.4.1 Approximate Mature Tree
Heights
10 to
20m | 20 to 30m | 30m to
60m |
---|
Acacias | But-But | Blue Gum |
English
Elm | Candlebark | Lemon Gum / Figs |
Manna
Gum | Palms | Karri |
Pepper
Tree | Planes | Pines |
Ash | Cedars | Cypress |
Willows | Sheoaks | Poplars |
Yate | Silky Oak | River
Gum |
Yellow Gum | Spotted
Gum | Sugar Gum |
Tree
roots in proximity to a dwelling can also create conditions conducive to the
ingress of termites and termite activity. It is strongly
recommended that any trees too close to a dwelling be removed.
Grounds Inspection Completed |
6. Roof Exterior
The Roof Exterior is the outer covering such as roof tiles, roof sheeting, and the like, together with their fastenings, cappings and flashings.
Inspection of roof coverings by the inspector climbing onto the roof is only performed if the inspector asseses it is safe to do so. Hight, pitch, roofing material, weather conditions etc. affect the type of inspection that can be undertaken.
6.1 Roof Coverings
Type of Roof Covering Inspection
| - An inspection of visible parts of the roof covering was made from ground level. No tests were undertaken.
- The roof covering was not inspected by climbing onto the roof due to height related safety considerations
|
Roof Covering DescriptionWhich Roof | |
Roofing Material | - Roll Formed Metal (Colorbond) Sheeting
|
7. The Exterior
7.1 Exterior Areas Not Inspected
This Section details any exterior areas that couldn't be accessed and were not included in the inspection.
All the normally accessible exterior areas permitted access |
7.2 Exterior Walls
This Section covers the outer walls of the dwelling viewed from the exterior. External walls can be categorised into Loadbearing and Non-loadbearing. A concrete block construction, for example, is loading bearing and the blocks and mortar are designed to support the roof loads and resist wind forces whereas in a brick- veneer construction the brickwork provides no supporting function and is installed for aesthetics and to keep the weather away from the structural timber or steel frame that supports the roof.
Exterior Wall DescriptionWhich Structure | - Exterior wall to the main building
|
Type Of Construction | |
Cladding | |
Finish | |
Exterior Walls DefectWhich Wall | - Exterior wall to the main building
|
Location | |
Element | |
Defect | - Dents, Marks, Scraches and the like
- Touch-ups required to paint defects as marked, but not limited to. Preparation and Repainting or touch ups as required
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | The extent was undetermined |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Photos | |
Exterior Walls DefectWhich Wall | - Exterior wall to the main building
|
Location | |
Element | |
Defect | - Touch-ups required to paint defects as marked, but not limited to. Preparation and Repainting as required
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | Widespread |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Photos | |
Exterior Walls DefectWhich Wall | - Exterior wall to the main building
|
Location | |
Element | |
Defect | - Dents, Marks, Scraches and the like
-
Touch-ups required to paint defects as marked, but not limited to. Preparation and Repainting or touch ups as required
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | The extent was undetermined |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Photos | |
Exterior Walls Inspection Completed |
7.3 Exterior Windows
This Section covers defects in windows when inspected from the outside.
Exterior Walls Inspection Completed |
7.4 Exterior Doors
This Section covers the exterior of External Doors including sliding glass doors if present.
Exterior Door DefectWhich Door | |
Location | - Southern side of the building
|
Element | |
Defect | - Door require cleaning and touch ups
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | Localised |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Photos | |
Exterior Doors Inspection Completed |
7.5 Rainwater Goods - Guttering and Downpipes
Rainwater Goods are roof plumbing that includes eaves gutters, down pipes, spreaders, flashing, spouts, collectors and the like.
Rainwater Good DefectWhich Building | |
Location | |
Element | |
Defect | - Defective
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | Localised |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Photos | |
Rainwater Good DefectWhich Building | |
Location | |
Element | |
Defect | - Remove screws and pop rivets from gutter and any other rubbish
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | The extent was undetermined |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Photos | |
Rainwater Goods Inspection Completed |
7.6 Exterior Stairs
Exterior Stairs are stairs outside the exterior walls of the building that typically run from the ground level to a landing or raised deck at the first-floor level.
Exterior Stairs Inspection Completed |
7.7 Exterior Platforms (Patios, Porches, Verandahs, Balconies and Decks)
Platform is a generic expression to cover all decks, patios, balconies, verandahs etc. attached to the exterior walls of the dwelling.
Exterior Platforms to the building were inspected from the ground level and from on the platform.
Exterior Platforms Inspection Completed |
7.8 Other Exterior Primary Elements
Other External Primary Elements are structural elements that are not included in the other external Sections above. These were inspected from the ground level.
Other Exterior Primary Elements Inspection Completed |
7.9 Other External Secondary and Finishing Elements
Other External Secondary and Finishing Elements are non-structural elements that are not included in the other external Sections above and include items such as eaves linings of soffits, barge boards, vent pipes, flashing, water heaters, AC units conduit and the like. These were inspected from the ground level.
Other External Secondary and Finishing Elements Inspection Completed |
8. Roof Void
This Section covers the roof space and roof frame where house designs that have a pitched roof and an accessible void under the roof covering and above the ceiling of the rooms below. Those roof designs such as flat, skillion and cathedral do not have accessible roof voids and are not inspected.
Roof voids are not designed to be traversed and contain many potential hazards. Anyone considering entering a roof void must only enter when they have assessed it is safe to do so. Safety hazards in roof voids include falling, electrical shock, trip hazards, chemical hazards, dust hazards, impalement hazards, heat stroke, and the like.
Regardless the type of inspection undertaken, inspection of roof voids are always limited by design and obstructions. Consiquently, building defects and timber pest activity may be present in areas that the inspector could not access safely.
Inspection of roof voids by the inspector climbing into the roof void is only performed if the inspector asseses it is safe to do so.
8.1 Roof Void
Type of Roof Space InspectionType of Roof Space Inspection | Partly accessible for inspection (e.g. part accessible pitched roof & part flat roof) or Inspection is limited by the presence of obstructions (e.g. insulation, sarking, heavy layers of dust and the like). |
Photos | |
9. The Interior
9.1 Interior Areas Not Inspected
This Section details any interior areas that couldn't be accessed and were not included in the inspection.
All the normally accessible interior areas permitted access |
9.2 Ceilings and Cornice
Cornice is the moulding or finishing element covering the intersection between the vertical wall and the horizontal Ceiling.
Ceilings are formed by sheets or boards attached to battens which are in turn attached to ceiling joists or the bottom cords of roof trusses. In newer constructions the ceiling may be attached directly to the bottom cords of trusses.
Ceilings And Cornice DefectLocation | |
Element | |
Defect | - Poorly finished
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | Localised |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Notes | |
Photos | |
Ceilings And Cornice DefectLocation | |
Element | |
Defect | - Paint touch up and or clean
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | Localised |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Notes | |
Photos | |
Ceilings and Cornice Inspection Completed |
9.3 Interior Walls
Interior Walls are both the interior surface of the perimeter loadbearing walls of the building and internal partition walls that may be loadbearing or non-loadbearing.
Interior Walls DefectLocation | - Ensuite
- Master bedroom
- Walk in robe
|
Element | |
Defect | - Dents, Marks, Scraches and the like
- Minor paintwork imperfections
- Touch-ups required to paint defects as marked, but not limited to. Preparation and Repainting or touch ups as required
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | The extent was undetermined |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Notes | |
Photos | |
Interior Walls DefectLocation | |
Element | |
Defect | - Dents, Marks, Scraches and the like
- Minor paintwork imperfections
- Touch-ups required to paint defects as marked, but not limited to. Preparation and Repainting or touch ups as required
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | The extent was undetermined |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Notes | |
Photos | |
Interior Walls Inspection Completed |
9.4 Floors And Skirtings
Skirtings are the mouldings or finishing elements covering the intersection between the vertical wall and the horizontal floor.
Note: The early signs of termite activity are often detected by sounding (tapping) skirtings. This sounding is only possible where the skirting is not obstructed and there is enough room for the consultant to undertake the sounding process.
Any tiled floors are also sounded for loose and or drummy tiles but only where not obsructed.
Floors & Skirtings DefectLocation | |
Element | |
Defect | - Drummy tiles
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | The extent was undetermined |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Photos | |
Floors and Skirtings Inspection Completed |
9.5 Interior Doors
This Section covers the interior side of external doors including sliding glass doors if present and interior doors including robes and cupboards.
Interior Doors DefectWhich Door | Doors |
Location | - Walk in robe
- Master bedroom
|
Element | |
Defect | - Install missing hardware
Minor touch to top of door
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | Localised |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Notes | |
Photos | |
Interior Doors DefectWhich Door | Doors |
Location | |
Element | |
Defect | - Including top and bottom edges must receive two coast of paint or sealer to prevent moisture absorption in accordance with manufactures specifications
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | Widespread |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Notes | |
Photos | |
Interior Doors Inspection Completed |
9.6 Interior Windows
This Section covers the interior side of windows.
Interior Windows Inspection Completed |
9.7 Built-in Fittings
Built-in Fittings include all built-in cupboards, vanities, shelving, etc.
Builtin Fittings Inspection Completed |
9.8 Other Interior Woodwork
Other Interior Woodwork includes any timber secondary or finishing elements not covered in the Sections above.
Other Interior Woodwork Inspection Completed |
9.9 Sanitary Fittings
Sanitary Fittings refers to the showers, baths, basins, water closets, bidets, etc. commonly found in toilets, bathrooms and en-suites.
Sanitary Fittings DefectWhich Fixture | |
Location | |
Element | |
Defect | - Remove debris
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | Localised |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Photos | |
Sanitary Fittings DefectWhich Fixture | |
Location | |
Element | |
Defect | - Not installed
|
Defect Category | Defect in Secondary or Finishing Element |
Severity | Minor |
Extent | Localised |
Recommendation | A further investigation is recommended by the following trades to determine the extent of work required and associated costs.
|
Photos | |
Sanitary Fittings Inspection Completed |
9.10 Other Interior Detail
Other Interior Detail is any defect not covered in the Sections above.
Other Interior Detail Inspection Completed |
10. Subfloor
Subfloor refers to any part of the structure which is below the lowest floor level. In a highset home this is the area under the dwelling. In a slab on ground home it is the concrete slab, its reinforcing steel and other components that form the foundation for the structure.
Subfloor voids under lowset homes are not designed for easy access and contain many potential hazards. Anyone considering entering the subfloor of a low set home should only enter when they have assessed it is safe to do so. Safety hazards in subfloors include electrical shock, trip hazards, chemical hazards, dust hazards, impalement hazards, heat stroke, entrapment, etc.
Inspection by the inspector entering the subfloor space is only performed if the inspector asseses it is safe to do so.
Note:Slab on ground homes do not have an accessible subfloor.
10.1 Sub Floor
Subfloor AccessSubfloor Space Access | Not accessible for inspection (e.g. where there is a slab-on-ground or infill slab construction). |
11. Terms and Conditions
11.1 Building Maintenance Responsibilities
To help protect against financial loss, it is strongly recommended that:
- Any defects identified in this inspection report be immediately controlled or rectified.
- Conditions conducive to structural damage and timber pest activity be immediately removed, rectified or monitored.
The importance of removing conditions conducive is often not fully appreciated and as a consequence, structural damage and timber pest activity have resulted in subsequent loss. It is also recommended that any high risk areas (e.g. where access was not gained or where areas were concealed by obstructions) be further investigated. Importantly, Standard AS 4349.1 Inspection of Buildings recognises that a standard property report is not a warranty against problems developing with the building in the future. Accordingly, a preventative maintenance program should be implemented for the property which includes systematic inspections, detection and prevention of incipient failure. In respect of timber pests, to help minimise the risk of any future loss, thorough regular inspections should undertaken at intervals not exceeding 12 months or more frequent inspections where the risk of timber pest attack is high or the building type is susceptible to attack. If you require further information on a risk management program, please do not hesitate to contact ABIS on 07 3804 1000.
Building Consultant means a person, business or company who is qualified and experienced to undertake a pre-purchase inspection in accordance with Australian Standard AS 4349.1-2007 "Inspection of Buildings. Part 1: Pre-Purchase Inspections ÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂâÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂÃÂàResidential Buildings". The consultant must also meet any Government licensing requirement, where applicable.
Building & Site (property reporting) means the inspection of the nominated residence together with relevant features including any car accommodation, detached laundry, ablution facilities and garden sheds, retaining walls more than 700 mm high, paths and driveways, steps, fencing, earth, embankments, surface water drainage and stormwater run-off within 30 m of the building, but within the property boundaries.
Building & Site (timber pest reporting) means the main building (or main buildings in the case of a building complex) and all timber structures (such as outbuildings, landscaping, retaining walls, fences, bridges, trees, tree stumps and timber embedded in soil) and the land within the property boundaries up to a distance of 50 metres from the main building(s).
Chemical Delignification means the breakdown of timber through chemical action.
Client means the person or persons, for whom the Report was carried out or their Principal (i.e. the person or persons for whom the report is being obtained).
Conditions Conducive to Structural Damage means noticeable building deficiencies or environmental factors that may contribute to the occurrence of Structural Damage.
Conditions Conducive to Timber Pest Activity means noticeable building deficiencies or environmental factors that may contribute to the presence of Timber Pests. Where Conditions Conducive to Timber Pest Activity are present and structural elements are involved, then Conditions Conducive to Structural Damage should also be considered present.
Finishing Elements means the fixtures, fittings and finishes applied or affixed to Primary Elements and Secondary Elements such as baths, water closets, vanity basins, kitchen cupboards, door furniture, window hardware, render, floor and wall tiles, trim or paint. The term "Finishing Elements" does not include furniture or soft floor coverings such as carpet and linoleum.
Incomplete Construction means where the construction is not complete in the work synonymous with construction (but does not include building services).
Instrument Testing (timber pest reporting) means where appropriate, the carrying out of Tests using the following techniques and instruments:
- electronic moisture detecting meter - an instrument used for assessing the moisture content of building elements
- thermal imaging camera - an instrument used to provide a thermal map of the heat energy radiated from visible surfaces to aid the detection of excessive moisture and termite activity
- probing - a technique where timber and other materials/areas are penetrated with a sharp instrument (e.g. bradawl or pocket knife), but does not include probing of decorative timbers or finishes, or the drilling of timber and trees
- sounding - a technique where timber is tapped with a solid object
Major Defect means defect of significant magnitude where rectification has to be carried out in order to avoid unsafe conditions, loss of utility or further deterioration of the property.
Minor Defect means defect other than a Major Defect.
No Defects Were Observed means that when comparing the inspected building with a typical example of its type and age, no defects, other than wear and tear normally associated with the ravages of time, were deemed by the inspector to warrant description and reporting. In older homes minor defects are not reported on in detail.
Primary Elements means those parts of the building providing the basic loadbearing capacity to the Structure, such as foundations, footings, floor framing, loadbearing walls, beams or columns. The term "Primary Elements" also includes other structural building elements including:
- those that provide a level of personal protection such as handrails
- floor-to-floor access such as stairways
- the structural flooring of the building such as floorboards
Readily Accessible Areas means:
- areas which can be easily and safely inspected without injury to person or property
- are up to 3.6 metres above ground or floor levels
- in roof spaces where the minimum area of accessibility is not less than 600 mm high by 600 mm wide
- subfloor spaces where the minimum area of accessibility is not less than 400 mm high by 600 mm wide providing the spaces or areas permit safe entry.
The term "readily accessible" also includes:
- accessible subfloor areas on a sloping site where the minimum clearance is not less than 150 mm high, provided that the areas is not more than 2 metres from a point with conforming clearance (i.e. 400 mm high by 600 mm wide)
- areas at the eaves of accessible roof spaces that are within the consultant's unobstructed line of sight and within arm's length from a point with conforming clearance (i.e. 600 mm high by 600 mm wide)
Secondary Elements means those parts of the building not providing loadbearing capacity to the Structure, or those non-essential elements which, in the main, perform a completion role around openings in Primary Elements and the building in general such as non-loadbearing walls, partitions, wall linings, ceilings, chimneys, flashings, windows, glazing or doors.
Serious Safety Hazard means any item that may constitute an immediate or imminent risk to life, health or property. Occupational, health and safety or any other consequence of these hazards has not been assessed.
Structural Damage means a significant impairment to the integrity of the whole or part of the Structure falling into one or more of the following categories:
- Structural Cracking and Movement - major (full depth) cracking forming in Primary Elements resulting from differential movement between or within the elements of construction, such as foundations, footings, floors, walls and roofs
- Deformation - an abnormal change of shape of Primary Elements resulting from the application of load(s)
- Dampness - the presence of moisture within the building, which is causing consequential damage to Primary Elements
- Structural Timber Pest Damage - structural failure, i.e. an obvious weak spot, deformation or even collapse of timber Primary Elements resulting from attack by one or more of the following wood destroying agents: chemical delignification; fungal decay; wood borers; and termites
Structure means the load bearing part of the building, comprising the Primary Elements.
Subterranean Termite Management Proposal means a written proposal in accordance with Australian Standard AS 3660.2 to treat a known subterranean termite infestation and/or manage the risk of concealed subterranean termite access to buildings and structures.
Tests (property reporting) means where appropriate, the carrying out of tests using the following procedures and instruments:
- Dampness Tests - additional attention to the visual examination was given to those accessible areas which the consultant's experience has shown to be particularly susceptible to damp problems. Instrument testing using electronic moisture detecting meter of those areas and other visible accessible elements of construction showing evidence of dampness was performed.
- Physical Tests - the following physical actions undertaken by the consultant: opening and shutting of doors, windows and drawers; operation of taps; water testing of shower recesses; and the tapping of tiles and wall plaster.
Tests (timber pest reporting) means additional attention to the visual examination was given to those accessible areas which the consultant's experience has shown to be particularly susceptible to attack by Timber Pests. Instrument Testing of those areas and other visible accessible timbers/materials/areas showing evidence of attack was performed.
Timber Pest Activity means telltale signs associated with "active" (live) and/or "inactive" (absence of live) Timber Pests at the time of inspection. The term "Timber Pest Activity" also includes timber pest damage i.e. noticeable impairments to the integrity of timber and other susceptible materials resulting from attack by Timber Pests.
Timber Pest Detection Consultant means a person who meets the minimum recommended competency standard set out in Australian Standard AS 4349.3 Inspections of Buildings. Part 3: Timber Pest Inspection Reports.
Timber Pests means one or more of the following wood destroying agents which attack timber in service and affect its structural properties:
- Fungal Decay - the microbiological degradation of timber caused by soft rot fungi and decay fungi, but does not include mould, which is a type of fungus that does not structurally damage wood.
- Wood Borers - wood destroying insects belonging to the order "Coleoptera" which commonly attack seasoned timber.
- Termites - wood destroying insects belonging to the order "Isoptera" which commonly attack seasoned timber.
As requested and agreed with the Client, the inspection carried out by a qualified Building Consultant and Timber Pest Detection Consultant ("The Consultant") is a New Construction Handover Report ("The Report").
The Terms on which this Report was prepared are set out in the following sub-sections: